CAROLINA BIOLOGICAL SUPPLY CO -- AMPICILLIN -- -
===================== Product Identification ===================== Product ID:AMPICILLIN MSDS Date:06/09/1998 FSC:NIIN:Submitter:D DG Status Code:A === Responsible Party === Company Name:CAROLINA BIOLOGICAL SUPPLY CO Address:2700 YORK RD City:BURLINGTON State:NC ZIP:27215-3387 Country:US Info Phone Num:800-227-1150 Emergency Phone Num:800-227-1150 Chemtrec Ind/Phone:(800)424-9300 CAGE:59896 === Contractor Identification === Company Name:CAROLINA BIOLOGICAL SUPPLY CO Address:2700 YORK RD Box:City:BURLINGTON State:NC ZIP:27215-3387 Country:US Phone:800-227-1150/910-584-0381 Contract Num:MDA414-00-P-4948 CAGE:59896 ============= Composition/Information on Ingredients ============= Ingred Name:AMPICILLIN CAS:69-52-3 Code:F RTECS #:XH8400000 = Wt:1. ===================== Hazards Identification ===================== LD50 LC50 Mixture:ORAL RAT LD50: > 5314 MG/KG Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO Health Hazards Acute and Chronic:EYE: MAY CAUSE IRRITATION. SKIN: MAY CAUSE IRRITATION. INGESTION: MAY CAUSE GASTROINTESTINAL DISCOMFORT. INHALATION: MAY CAUSE IRRITATION TO RESPIRATORY TRACT. TARGET ORGANS:N/A. Explanation of Carcinogenicity:LISTED BY IARC AS A POSSIBLE CARCINOGEN Effects of Overexposure:NONE PROVIDED BY MFR. Medical Cond Aggravated by Exposure:THERE ARE REPORTS OF SERIOUS & SOMETIMES FATAL HYPERSENSITIVITY (ANAPHYLACIC) REACTIONS OCCURRING IN PEOPLE RECEIVING PENICILLIN THERAPY BY THE PARENTAL ROUTE ALTHOUGH IT HAS OCCURRED VIA ORAL ADMINISTR ======================= First Aid Measures ======================= First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINS, RAISING & LOWERING EYELIDS OCCASIONALLY. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN: THOROUGHLY WASH EXPOSED AREA FOR AT LEAST 15 MINS. REMOVE CONTA MINATED CLOTHING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INGESTION: IF SWALLOWED, IF CONSCIOUS, GIVE PLENTY OF WATER. IMMEDIATELY CALL A PHYSICIAN OR POISON CONTROL CENTER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING IS (SEE OTHER INFORMATION) ===================== Fire Fighting Measures ===================== Lower Limits:NO DATA Upper Limits:NO DATA Extinguishing Media:USE DRY CHEMICAL, CO2 OR APPROPRIATE FOAM. Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR FULL PROTECTIVE EQUIPMENT & NIOSH APPROVED SELF CONTAINED BREATHING APPARATUS Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES UNDER FIRE CONDITIONS. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA OF SPILL. EMININATE ALL SOURCES OF IGNITION. REMOVE ALL NON-ESSENTIAL PERSONNEL FROM AREA. CLEAN-UP PERSONNEL SHOULD WEAR PROPER PROTECTIVE EQUIPMENT & CLOTHING. ABSORB MATERIAL WITH SU ITABLE ABSORBANT & CONTAINERIZE FOR DISPOSAL Neutralizing Agent:NONE PROVIDED BY MFR. ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP OUT OF DIRECT SUNLIGHT & AWAY FROM HEAT. Other Precautions:NONE PROVIDED BY MFR. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:A NIOSH/MSHA CHEMICAL CARTRIDGE RESPIRATOR SHOULD BE WORN IF PEL OR TLV IS EXCEEDED. Ventilation:LOCAL EXHAUST: YES. MECHANICAL (GENERAL): YES. SPECIAL:NO. OTHER:NO. Protective Gloves:RUBBER, NEOPRENE, PVC, OR EQUIVALENT Eye Protection:SPLASH PROOF CHEMICAL SAFETY GOGGLES SHOULD BE WORN AT ALL TIMES Other Protective Equipment:LAB COAT, EYE WASH, AND SAFETY SHOWER Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. Supplemental Safety and Health CAROLINA BIOLOGICAL ITEM#: 21-1146A. SEE MFN 1&3. OTHER PRODUCT CODES:21-1140, 21-6880. ================== Physical/Chemical Properties ================== HCC:T6 Melt/Freeze Pt:=215.C, 419.F Decomp Temp:Decomp Text:NONE PROVIDED BY MFR. pH:NONE PROVIDED Viscosity:NONE PROVIDED BY MFR. Solubility in Water:SLIGHT Appearance and Odor:CLEAR LIQUID Corrosion Rate:NONE PROVIDED BY MFR ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES OXIDIZERS Stability Condition to Avoid:HEAT, SUNLIGHT Hazardous Decomposition Products:CO Conditions to Avoid Polymerization:WILL NOT OCCUR =================== Toxicological Information =================== Toxicological Information:ORAL RAT LD50:>5314MG/KG. LISTED BY IARC AS A POSSIBLE CARCINOGEN. ===================== Ecological Information ===================== Ecological:EPA WASTE NUMBERS:NONE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE & LOCAL REGULATIONS. ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE. EPA WASTE NUMBER:NONE. =================== MSDS Transport Information =================== Transport Information:NON-REGULATED. ===================== Regulatory Information ===================== SARA Title III Information:SARA SEC 313/312 REPORTING:ACUTE. SARA EHS SEC 302 TPQ:NO. SARA SEC 313 CHEMICALS:NO. Federal Regulatory Information:CERCLA SEC 103 RQ LBS:NO. RCRA SEC 261.33:NO. ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.